Customization: | Available |
---|---|
Breaking Capacity: | Low Voltage Circuit Breakers |
Operation: | Electric Type |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Integrated Protection Functions: Offers both short-circuit and overload protection for enhanced safety.High Breaking Capacity: Rated breaking capacity up to 6kA, ensuring reliable disconnection in fault conditions.
Polarity-Free Connection: No distinction between positive and negative poles-supports reverse wiring, simplifying installation.
Rated Current up to 63A: Stable performance across various current ranges.
Extra-Wide Contact Gap (>9mm): Fast arc quenching with secure isolation.
Labyrinth Arc Chamber: Enhances arc suppression and improves breaking performance.
Magnetic Blowout Design: U-shaped magnetic structure for better arc movement and extinguishing.
7-Point Riveted Terminals: Strengthened connection points for stable and reliable wiring.
Busbar Compatibility: Supports busbar wiring for neater and more efficient electrical connections.
Modern & Functional Design: A unique, practical appearance that reflects professional-grade quality.
Complete Accessory Set: Fully compatible with DC photovoltaic and energy storage systems.
Item | Specification |
---|---|
Rated Insulation Voltage (Ui) | 1250V |
Rated Operational Voltage (Ue) | DC(1P): 15V / 60V / 100V / 180V / 250VDC(2P): 125V / 375V / 550V / 600V / 800VDC(3P): 750V / 800VDC(4P): 800V / 1000V / 1200V |
Rated Current (In) | 6A / 10A / 16A / 20A / 25A / 32A / 40A / 50A / 63A |
Frame Current | 63A |
Breaking Capacity (Ics = Icu) | 6kA (2P 800V / 4P 1200V: 2kA) |
Trip Curve Type | B / C |
Mechanical Life | 8500 operations |
Electrical Life | 1500 times (< DC125V/1P, < DC250V/2P); 1000 times (other voltages) |
Impulse Withstand Voltage (Uimp) | 6kV |
Overvoltage Category | III |
Pollution Degree | 3 |
Protection Degree | IP40 (device body), IP20 (terminals) |
Humidity Resistance | Class 2 / ≤95% RH |
Shock & Vibration Resistance | IEC60068-2-6 / IEC60068-2-27 |
Ambient Operating Temperature | -30°C ~ +70°C |
Storage Temperature | -40°C ~ +85°C |
Altitude Limit | ≤2000m |
Installation | DIN rail 35mm |
Accessories | OF, ISD, MX, MN, MX+OF |
MX Control Voltage | DC: 12V / 24V / 220V; AC: 110V / 220V / 380V (≥75W recommended) |
MN Rated Voltage | AC220V / AC380V |
Unit Weight | 0.12 kg/piece |
Certifications | IEC 60947-2 / GB/T 14048.2 |
Accelerated Installations
Enhanced Safety Measures
Extended Product Lifespan
Innovatively Intelligent Structure
Sophisticated, Professional Aesthetic
Photovoltaic Installation Projects
Off-Grid Solar System Implementations
Energy Storage Unit Management
DC Power Distribution Panels